The Prague Post - As world heats up, UN cools itself the cool way: with water

EUR -
AED 4.272483
AFN 80.853073
ALL 97.665328
AMD 445.199497
ANG 2.082185
AOA 1066.812425
ARS 1581.61212
AUD 1.78504
AWG 2.094071
AZN 1.975687
BAM 1.955813
BBD 2.342866
BDT 141.500942
BGN 1.954687
BHD 0.438495
BIF 3429.041155
BMD 1.163373
BND 1.498842
BOB 8.038157
BRL 6.362025
BSD 1.163233
BTN 102.621683
BWP 15.681172
BYN 3.92421
BYR 22802.105732
BZD 2.339466
CAD 1.603878
CDF 3334.804697
CHF 0.936829
CLF 0.028874
CLP 1132.706449
CNY 8.305902
CNH 8.307087
COP 4659.482335
CRC 588.116552
CUC 1.163373
CUP 30.829378
CVE 110.461781
CZK 24.490109
DJF 206.754844
DKK 7.463182
DOP 73.525797
DZD 151.126655
EGP 56.445917
ERN 17.450591
ETB 165.95518
FJD 2.630334
FKP 0.859049
GBP 0.86958
GEL 3.135235
GGP 0.859049
GHS 13.670006
GIP 0.859049
GMD 83.762384
GNF 10074.808025
GTQ 8.916059
GYD 243.262664
HKD 9.082917
HNL 30.709629
HRK 7.534697
HTG 152.184283
HUF 395.651515
IDR 19139.633836
ILS 3.942729
IMP 0.859049
INR 102.375464
IQD 1524.018291
IRR 48919.823774
ISK 143.607129
JEP 0.859049
JMD 186.591242
JOD 0.824808
JPY 172.840543
KES 150.657511
KGS 101.657948
KHR 4659.308025
KMF 492.68993
KPW 1047.007807
KRW 1624.068646
KWD 0.355946
KYD 0.969311
KZT 628.19418
LAK 25230.652726
LBP 104188.750357
LKR 351.529893
LRD 235.059908
LSL 20.603155
LTL 3.435137
LVL 0.703712
LYD 6.293838
MAD 10.52276
MDL 19.332212
MGA 5206.092501
MKD 61.52827
MMK 2442.319185
MNT 4185.24298
MOP 9.352902
MRU 46.511241
MUR 53.340489
MVR 17.919176
MWK 2020.778395
MXN 21.792996
MYR 4.92165
MZN 74.351705
NAD 20.602969
NGN 1788.929793
NIO 42.813318
NOK 11.676266
NPR 164.195093
NZD 1.985127
OMR 0.447315
PAB 1.163233
PEN 4.116593
PGK 4.923974
PHP 66.70781
PKR 327.896619
PLN 4.263865
PYG 8402.05591
QAR 4.235609
RON 5.079748
RSD 117.181944
RUB 93.708437
RWF 1682.236984
SAR 4.365348
SBD 9.575246
SCR 16.503102
SDG 698.599579
SEK 11.010503
SGD 1.499756
SHP 0.914228
SLE 27.10726
SLL 24395.34234
SOS 664.867895
SRD 44.967851
STD 24079.466908
STN 24.867092
SVC 10.178068
SYP 15125.62995
SZL 20.602897
THB 37.603739
TJS 10.94572
TMT 4.071805
TND 3.354877
TOP 2.724733
TRY 47.895822
TTD 7.896222
TWD 35.784225
TZS 2905.339585
UAH 48.107607
UGX 4119.027409
USD 1.163373
UYU 46.54051
UZS 14454.906063
VES 173.669272
VND 30649.054873
VUV 138.914638
WST 3.096669
XAF 655.969823
XAG 0.028438
XAU 0.00033
XCD 3.144073
XCG 2.096459
XDR 0.810902
XOF 650.907152
XPF 119.331742
YER 279.384123
ZAR 20.600155
ZMK 10471.775646
ZMW 27.562776
ZWL 374.605548
  • CMSC

    -0.0810

    23.659

    -0.34%

  • BCC

    -1.0000

    85.78

    -1.17%

  • SCS

    0.0300

    16.77

    +0.18%

  • BCE

    -0.5300

    24.43

    -2.17%

  • GSK

    -0.7100

    38.96

    -1.82%

  • AZN

    0.2900

    80.19

    +0.36%

  • BTI

    -1.6500

    55.24

    -2.99%

  • RIO

    -0.8300

    61.89

    -1.34%

  • RBGPF

    -1.0000

    76

    -1.32%

  • NGG

    -2.5900

    67.98

    -3.81%

  • CMSD

    0.0100

    23.63

    +0.04%

  • BP

    0.0000

    35.23

    0%

  • JRI

    -0.0900

    13.51

    -0.67%

  • RYCEF

    0.0800

    14.35

    +0.56%

  • RELX

    -1.2300

    45.44

    -2.71%

  • VOD

    -0.2400

    11.72

    -2.05%

As world heats up, UN cools itself the cool way: with water
As world heats up, UN cools itself the cool way: with water / Photo: ANGELA WEISS - AFP

As world heats up, UN cools itself the cool way: with water

Deep in the bowels of the UN headquarters, a pump sucks in huge amounts of water from the East River to help cool the complex with an old but energy-efficient mechanism.

Text size:

As more and more people want to stay cool in a planet that is steadily heating up, energy experts point to this kind of water-based system as a good alternative to air conditioning. But in many cases they are hard to set up.

The system has been part of the New York complex since it opened in the 1950s, chief building engineer Michael Martini told AFP during a tour of the cooling equipment.

The system, overhauled with the rest of the complex from 2008 to 2014, cools the UN center using less energy than a conventional air conditioning system. UN policy is to bring the air temperature down to about 24 degrees Celsius, or 75 degrees Fahrenheit.

In summer in New York, the river running beside the UN headquarters -- it is actually a salt water estuary -- stays much cooler than the surrounding air, which can reach 100 degrees. So cooling the building eats up less energy.

As many as 26,000 liters per minute (7,000 gallons) of water flow through fiber glass pipes to the complex's cooling plant, which uses it and a refrigerant gas to produce cold.

The system has two independent loops to prevent contamination of the water that flows back into the river at a higher temperature, said the head of the cooling system, David Lindsay.

Looking at the gleaming glass tower of the UN headquarters and the dome of the General Assembly, you would never know that the East River serves this purpose for the UN and is more than just part of the scenery.

The UN's New York headquarters is not its only building that depends on water.

In Geneva, its Palais de Nations features a cooling system that uses water from Lake Geneva. And the UN City complex in Copenhagen, which houses 10 UN agencies, depends on cold seawater that almost eliminates the need for electricity to cool the place.

This a huge benefit compared to the estimated two billion air conditioning units installed around a world.

- Why so rare? -

With the number of air conditioners due to increase so as to help people who are more and more exposed to dangerous temperatures, energy consumption for the purpose of cooling has already tripled since 1990, says the International Energy Agency, which wants more efficient systems.

Examples of these are centralized air conditioning networks using electricity, geothermal systems or ones that use water, like the UN complex in New York.

This latter system "has not been deployed as much as it should be for the issues we face today," said Lily Riahi, coordinator of Cool Coalition, a grouping of states, cities and companies under the aegis of the United Nations.

Some big organizations have been able to run such systems on their own, like the United Nations or Cornell University in New York State, which relies on water from Lake Cayuga.

But for the most part these systems require a lot of coordination among multiple stakeholders, said Riahi.

"We know it's technically possible, and we know actually there are many cases that prove the economics as well," said Rob Thornton, president of the International District Energy Association, which helps develop district cooling and heating networks.

"But it requires someone, some agent, whether it's a champion, a city, or a utility or someone, to actually undertake the aggregation of the market," he said.

"The challenge is just gathering and aggregating the customers to the point where there's enough, where the risk can be managed," Thornton said.

He cited Paris as an example, which uses the Seine River to run Europe's largest water-based cooling grid.

These networks allow for the reduced use toxic substances as coolants, and lower the risk of leaks.

And they avoid emissions of hot air -- like air conditioning units spew -- into cities already enduring heat waves.

But hot water from cooling units, when dumped back into rivers and other bodies of water, is dangerous for aquatic ecosystems, environmentalists say.

"This challenge is quite small, compared to the discharge from nuclear plants," said Riahi, adding the problem can be addressed by setting a temperate limit on this water.

S.Janousek--TPP